From: Christian Weiske Date: Sun, 28 Dec 2014 06:36:48 +0000 (+0100) Subject: add heating setting X-Git-Url: https://git.cweiske.de/munin-heatpump.git/commitdiff_plain/eeaa050a7358140291995faedaa8c1afed3d813d add heating setting --- diff --git a/heatpump-dimplex-wpm_ b/heatpump-dimplex-wpm_ index a9a0d6c..d981115 100755 --- a/heatpump-dimplex-wpm_ +++ b/heatpump-dimplex-wpm_ @@ -107,6 +107,18 @@ if [ "$1" = "config" ]; then echo 'reqwater.label Anforderung Warmwasser' echo 'reqwater.draw LINE1' + #settings: heating level + echo 'multigraph heatpump_dimplex_wpm_heating_level' + echo 'graph_title Heizungseinstellung' + echo 'graph_args --base 1000 --lower-limit 0 --upper-limit 38' + echo 'graph_vlabel Einstellung' + echo 'graph_info Shows the heating setting' + echo 'graph_scale no' + echo 'graph_category settings' + + echo 'circuit1.label Heizkreis 1' + echo 'circuit1.draw LINE1' + exit 0 fi @@ -153,3 +165,7 @@ echo 'multigraph heatpump_dimplex_wpm_states' echo reqheating.value `echo "$data" | grep DIGITAL/136 | cut -d" " -f2` water=`echo "$data" | grep DIGITAL/140 | cut -d" " -f2` echo reqwater.value `echo $(($water * 2))` + +#Settings: Heating level +echo 'multigraph heatpump_dimplex_wpm_heating_level' +echo circuit1.value `echo "$data" | grep 'INTEGER/1 ' | cut -d" " -f2`