add LICENSE file
[munin-heatpump.git] / heatpump-dimplex-wpm_
index 169fd76063993a122bc1e0faaeddb01ae5c47324..d981115ef17f14802693c22d807dc27b4c6ddbd9 100755 (executable)
@@ -52,14 +52,15 @@ if [ "$1" = "config" ]; then
 
     #Outdoor temperature
     echo 'multigraph heatpump_dimplex_wpm_outtemp'
-    echo 'graph_title Außentemperatur'
+    echo 'graph_title Aussentemperatur'
     echo 'graph_args --base 1000'
     echo 'graph_vlabel °C'
     echo 'graph_info Zeigt die gemessene Außentemperatur an'
     echo 'graph_scale no'
     echo 'graph_category sensors'
 
-    echo 'outtemp.label Außentemperatur'
+    echo 'outtemp.label Aussentemperatur'
+    echo 'outtemp.draw LINE1'
 
     #Heating temperatures
     echo 'multigraph heatpump_dimplex_wpm_heating'
@@ -70,9 +71,12 @@ if [ "$1" = "config" ]; then
     echo 'graph_scale no'
     echo 'graph_category sensors'
 
-    echo 'returntargettemp.label Rücklaufsolltemperatur'
-    echo 'returntemp.label Rücklauftemperatur'
+    echo 'returntargettemp.label Ruecklaufsolltemperatur'
+    echo 'returntargettemp.draw LINE2'
+    echo 'returntemp.label Ruecklauftemperatur'
+    echo 'returntemp.draw LINE1'
     echo 'influxtemp.label Vorlauftemperatur'
+    echo 'influxtemp.draw LINE1'
 
     #Water temperature
     echo 'multigraph heatpump_dimplex_wpm_water'
@@ -84,7 +88,9 @@ if [ "$1" = "config" ]; then
     echo 'graph_category sensors'
 
     echo 'watertargettemp.label Solltemperatur'
+    echo 'watertargettemp.draw LINE2'
     echo 'watertemp.label Warmwassertemperatur'
+    echo 'watertemp.draw LINE1'
 
 
     #On/off states
@@ -97,7 +103,21 @@ if [ "$1" = "config" ]; then
     echo 'graph_category sensors'
 
     echo 'reqheating.label Anforderung Heizung'
+    echo 'reqheating.draw LINE1'
     echo 'reqwater.label Anforderung Warmwasser'
+    echo 'reqwater.draw LINE1'
+
+    #settings: heating level
+    echo 'multigraph heatpump_dimplex_wpm_heating_level'
+    echo 'graph_title Heizungseinstellung'
+    echo 'graph_args --base 1000 --lower-limit 0 --upper-limit 38'
+    echo 'graph_vlabel Einstellung'
+    echo 'graph_info Shows the heating setting'
+    echo 'graph_scale no'
+    echo 'graph_category settings'
+
+    echo 'circuit1.label Heizkreis 1'
+    echo 'circuit1.draw LINE1'
 
     exit 0
 fi
@@ -111,7 +131,7 @@ fi
 xslfile=paths.xsl
 if [ ! -f "$xslfile" ]; then
     shell="`readlink -f "$0"`"
-    path="`dirname "$0"`"
+    path="`dirname "$shell"`"
     xslfile="$path/paths.xsl"
     if [ ! -f "$xslfile" ]; then
         echo 'Could not find paths.xsl'
@@ -145,3 +165,7 @@ echo 'multigraph heatpump_dimplex_wpm_states'
 echo reqheating.value `echo "$data" | grep DIGITAL/136 | cut -d" " -f2`
 water=`echo "$data" | grep DIGITAL/140 | cut -d" " -f2`
 echo reqwater.value `echo $(($water * 2))`
+
+#Settings: Heating level
+echo 'multigraph heatpump_dimplex_wpm_heating_level'
+echo circuit1.value `echo "$data" | grep 'INTEGER/1 ' | cut -d" " -f2`